| प्यारामीटर | मूल्य |
|---|---|
| वस्तु | Specifications |
| टिप्पणी | Use the safety light curtain monitoring information obtained via IO-Link only for diagnostic purposes. Do not use it for safety control purposes. |
| तौल | 270 g approx. |
| उत्पादन | IO-Link communication unit for safety light curtain SF4D series |
| सामाग्री | Main unit case: PA66 (with glass)Base plate: SPCC + PlatingProduct model nameplate: PolyesterExternal connection connector: Brass + Plating |
| कार्यहरू | • IO-Link communication function• Safety light curtain setting data copy function (Note)Note :• The internal memory (nonvolatile) of this product has a service life. Settings cannot be configured more than 100,000 times.• This product cannot be used to directly enter settings from the IO-Link master unit to a safety light curtain using IO-Link communication.• The safety light curtain setting data copy function is designed only for use in maintenance / replace of safety light curtains.Use the copy function only for loading the setting data of the previous safety light curtain to a new unit. Loading the data to a device other than a newly installed safety light curtain may result in improper device operation.• This function cannot be used unless the product is connected with the IO-Link master unit and IO-Link communication is used. |
| भाग नम्बर | SFD-WL3 |
| उत्पादनको नाम | IO-Link Communication Unit |
| उत्पादन नम्बर | SFD-WL3 |
| परिवेशको आर्द्रता | 30 to 85% RH, Storage: 30 to 95% RH |
| प्रदूषणको डिग्री | 3 |
| सञ्चालन उचाइ | 2,000 m6561.68 ftor lessNote : Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| परिवेशको तापक्रम | -10 to +55℃14 to 131℉(No dew condensation or icing allowed),Storage: -25 to +60℃-13 to 140℉ |
| सुरक्षाको डिग्री | IP64 |
| लागू हुने नियमहरू | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| अतिरिक्त भोल्टेज श्रेणी | I |
| जडानयोग्य एकाइहरूको संख्या: यो उत्पादन | 1 unit |
| वातावरणीय प्रतिरोध: झट्का प्रतिरोध | 300 m/s2acceleration (30 G approx.) in X, Y, and Z directions three times eachMalfunction resistance 100 m/s2acceleration (10 G approx.) in X, Y, and Z directions 1,000 times each |
| आपूर्ति भोल्टेज: IO-लिङ्क सञ्चार पक्ष | 24V DC+20-25% Ripple P-P 10 % or less |
| जडान विधि: IO-लिङ्क सञ्चार पक्ष | 4-core cable with M12 connector (commercially available product) |
| वातावरणीय प्रतिरोध: कम्पन प्रतिरोध | 10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions for two hours eachMalfunction resistance 10 to 55 Hz, 0.75 mm0.030 indouble amplitude in X, Y, and Z directions twenty times each |
| हालको खपत: IO-लिङ्क सञ्चार पक्ष | 30 mA or less |
| वातावरणीय प्रतिरोध: इन्सुलेशन प्रतिरोध | 20 MΩ or more, with 500 V DC megger, between all supply terminals connected together and enclosure |
| सञ्चार विधि: IO-लिङ्क सञ्चार पक्ष | IO-Link specifications: Ver. 1.1Baud rate: COM3 (230.4 kbps)Data length: 18 bytes, process data (PD)Minimum cycle time: 1.5 ms |
| जडान: सुरक्षा प्रकाश पर्दा सञ्चार पक्ष | 8-core cable for safety light curtain (optional) |
| वातावरणीय प्रतिरोध: डाइलेक्ट्रिक शक्ति भोल्टेज | 1,000 V AC for one minute, between all supply terminals connected together and enclosure |
| आपूर्ति भोल्टेज: सुरक्षा प्रकाश पर्दा संचार पक्ष | 24V DC+20-30% Ripple P-P 10 % or less |
| हालको खपत: सुरक्षा प्रकाश पर्दा सञ्चार पक्ष | 15 mA or less |
| सञ्चार विधि: सुरक्षा प्रकाश पर्दा सञ्चार पक्ष | RS-485 bidirectional communication (dedicated protocol) |
| जडान गर्न मिल्ने एकाइहरूको संख्या: श्रृंखला जडानमा सुरक्षा प्रकाश पर्दाहरू | Up to 5 units (total number of beam channels 256 or less) |