| प्यारामीटर | मूल्य |
|---|---|
| वस्तु | Specifications |
| तौल | Net weight: 200 g approx. |
| विवरणहरू | Slim type control unit |
| उत्पादन | Exclusive Control Unit for Safety Light Curtain |
| फ्यूज मूल्याङ्कन | Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down |
| भाग नम्बर | SF-C13 |
| उत्पादनको नाम | Exclusive Control Unit for Safety Light Curtain SF-C10 |
| पावर भोल्टेज | 24 V DC ±10 % Ripple P-P 10 % or less / 100 mA or less (without safety light curtain) |
| प्रतिक्रिया समय | 10 ms or less |
| सुरक्षा आउटपुट | NO contact × 3 (13-14, 23-24, 33-34) |
| उत्पादन नम्बर | SF-C13 |
| परिवेशको आर्द्रता | 30 to 85 % RH, Storage: 30 to 95 % RH |
| प्रदूषणको डिग्री | 2 |
| सहायक आउटपुटहरू | Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path) |
| घेरा सामग्री | ABS |
| परिवेशको तापक्रम | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉ |
| जडान टर्मिनल | Spring-cage terminal |
| हालको खपत | 100 mA or less (without light curtain) |
| ओभरभोल्टेज श्रेणी | II |
| कम्पन प्रतिरोध | Resistance / malfunction 10 to 55 Hz frequency, 0.35 mm0.014 inamplitudein X, Y, and Z directions for twenty times each |
| ट्रेलिङ एज प्रकार्य | Incorporated |
| सूचकहरू: गल्ती (FAULT) | Yellow LED (blinks when fault occurs) |
| लागू हुने मापदण्डहरू: जापान | JIS B 9704-1 (Type 4), JIS B 9705-1(Category 4), |
| ध्रुवीयता चयन प्रकार्य | Incorporated (Cable connection allows selection of plus/minus ground)Minus ground: Correspond to PNP output safety light curtainPlus ground: Correspond to NPN output safety light curtain(Note:Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.) |
| सूचकहरू: विद्युत आपूर्ति (Ui) | Green LED (lights up when the power is ON) |
| सूचकहरू: सुरक्षा आउटपुट [आउट] | Green LED (lights up when safety output is closed)(Note:The operation indicator is marked as "Enabling" on the unit forSF-C12.) |
| सीई मार्किंग निर्देशन अनुपालन | Machinery Directive, Low Voltage (SF-C11/C13 only) Directive, EMC Directive, RoHS Directive |
| बाह्य रिले मनिटर प्रकार्य | Incorporated |
| लागू हुने मापदण्डहरू: युरोप (EU) | EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe)(Note:SF-C11andSF-C13comply with UL 1998 (Class 2).) |
| सुरक्षा आउटपुट: सम्पर्क प्रतिरोध | 100 mOhm or less (initial value) |
| जडान गर्न मिल्ने सुरक्षा प्रकाश पर्दाहरू | Safety light curtain manufactured by Panasonic Industrial Devices SUNX |
| सूचकहरू: इन्टरलक (INTER_LOCK) | Yellow LED (lights up when enabling contacts are opened) |
| सुरक्षा उत्पादन: विद्युतीय जीवनकाल | 100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
| सुरक्षा उत्पादन: यान्त्रिक जीवनकाल | 10,000,000 times or more (open/close frequency of 180 times/min)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.) |
| लागू हुने मापदण्डहरू: उत्तर अमेरिका | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) (Note:SF-C11andSF-C13comply with UL 1998 (Class 2).) |
| सुरक्षा आउटपुट: अनुप्रयोग कोटी | AC-15, DC-13 (IEC 60947-5-1) |
| अर्धचालक सहायक आउटपुट (AUX) | PNP open-collector transistor・Max. source current: 60 mA・Applied voltage: same as supply voltage(between the semiconductorauxiliary output and +V)・Residual voltage: 2.3 V or less(at source current 60 mA)Leakage current: 2 mA or less |
| पिक-अप ढिलाइ (स्वचालित रिसेट / म्यानुअल रिसेट) | 80 ms or less / 90 ms or less |
| सुरक्षा आउटपुट: सम्पर्क सामग्री / सम्पर्कहरू | AgSnO, self cleaning, positively driven |
| लागू हुने मापदण्डहरू: अन्तर्राष्ट्रिय मापदण्ड | IEC 61496-1 (Type 4) |
| सुरक्षा आउटपुट: सम्पर्क सुरक्षा फ्यूज मूल्याङ्कन गरिएको | 4 A (slow blow) |
| वातावरणीय प्रतिरोध: सुरक्षाको डिग्री | Enclosure: IP40Terminal: IP20 |
| सहायक आउटपुट: सम्पर्क सुरक्षा फ्यूज मूल्याङ्कन गरिएको | 2 A (slow blow) |
| सहायक आउटपुट: मूल्याङ्कन गरिएको सञ्चालन भोल्टेज / वर्तमान | 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) |
| अर्धचालक सहायक आउटपुट (AUX): आउटपुट सञ्चालन | On when the safety light curtain is interrupted |
| सुरक्षा आउटपुट: मूल्याङ्कन गरिएको सञ्चालन भोल्टेज (Ue) / मूल्याङ्कन गरिएको सञ्चालन वर्तमान (le) | 4 A / 30 V DC, 4 A / 230 V AC, resistive load (For inductive load, during contact protection) Min. applicable load: 10 mA (at 24 V DC)(Note:If severalSF-C11orSF-C13units are being used in a line together, leavea space of 5 mm0.197 inor more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs below.) |