| प्यारामीटर | मूल्य |
|---|---|
| Ue | |
| डीसी | Resistive load (DC-12) |
| अर्थात् | AC |
| B10D का थप वस्तुहरू | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| वस्तु | Specifications |
| केबल | UL style 2464, No.22 AWG 12-core |
| तौल | Approx. 680 g |
| उत्पादन | Safety door switch with key |
| सामाग्री | Enclosure : PA66 |
| सुरक्षा | IP 65 (IEC 60529) |
| भाग नम्बर | SG-B2-K2CC-5 |
| केबल लम्बाइ | 5m16.404 ft |
| उत्पादनको नाम | Safety door switch with key SG-B2 |
| उत्पादन नम्बर | SG-B2-K2CC-5 |
| इन्टरलक बल | 1,400 N min. (GS-ET-19)(Note)(500 N min. : SG-K24 actuator)(Note): The actuator locking strength is rated at 1,400 N of static load. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| झट्का प्रतिरोध | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| सम्पर्क प्रतिरोध | 700 mΩ max. (initial value, 5 m16.404 ftcable) |
| सम्पर्क व्यवस्था | |
| सञ्चालन आवृत्ति | 900 operations/hour |
| लागू हुने मापदण्डहरू | EN 1088, IEC 60947-5-1, EN 60947-5-1,GS-ET-19, UL 508, CSA C22.2 No.14 |
| प्रत्यक्ष उद्घाटन बल | 80 N min. |
| साँचो हटाउने स्थिति | C(removable in LOCK position) |
| कम्पन प्रतिरोध | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| लागू हुने निर्देशनहरू | Machinery directive (2006/42/EC)Low voltage directive (2006/95/EC) |
| प्रत्यक्ष उद्घाटन यात्रा | 11 mm0.433 inmin. (actuator : SG-K21)12 mm0.472 inmin. (for other actuators) |
| विद्युतीय टिकाउपन | 100,000 operations min. (AC-12, 250 V 1 A)1,000,000 operations min. (AC/DC 24 V 100 mA)(900 operations/hour) |
| यान्त्रिक स्थायित्व | 1,000,000 operations min. (GS-ET-19)Rear unlocking button : 3,000 operations min. (Type SG-B2-□-L5) |
| तापीय धारा (Ith) | ・2.5 A・Ambient temperature :-25 to +60 ℃-13 to +140 ℉: 2.5 A max.+60 to +65 ℃+140 to +149 ℉: 1.5 A max.+65 to +70 ℃+149 to +158 ℉: 1.0 A max. |
| आगमनात्मक भार (AC-15) | - |
| आगमनात्मक भार (DC-13) | 2.3A |
| एक्चुएटर सञ्चालन गति | 0.05 to 1.0 m/sec. |
| कुञ्जी: प्रत्यक्ष खोल्ने बल | 0.6 N・m min. |
| कुञ्जी: कुञ्जी तन्य शक्ति | 1.0 N・m min. |
| कुञ्जी: प्रत्यक्ष उद्घाटन डिग्री | 60°min. |
| कुञ्जी: यान्त्रिक स्थायित्व | 100,000 operations min. |
| मूल्याङ्कन गरिएको इन्सुलेशन भोल्टेज (Ui) | 250 V(Note): Ratings approved by UL, c-UL : 125 V |
| कुञ्जी: कुञ्जी सञ्चालन स्थायित्व | 10,000 operations min. |
| कुञ्जी: सञ्चालन विशिष्टताहरू | 2 positions |
| सञ्चालन अवस्था: उचाइ | 2,000 m6,561.68 ftmax. |
| विद्युतीय झट्का सुरक्षा वर्ग | Class II (IEC 61140)(Note), 回(double-insulated)(Note): Basic insulation of 2.5 kV impulse withstand voltage is ensured between different contact circuits.When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| सर्ट-सर्किट सुरक्षात्मक उपकरण | Use 250 V / 10 A fast acting type fuse |
| आवेग प्रतिरोधी भोल्टेज (Uimp) | 2.5 kV |
| सर्तगत सर्ट-सर्किट करेन्ट | 50 A (250 V) |
| सञ्चालन अवस्था: परिवेशको आर्द्रता | 45 to 85 % RH |
| सञ्चालन अवस्था: प्रदूषण डिग्री | 3 (Inside 2) |
| लागू हुने मापदण्डहरू: प्रयोगको लागि मापदण्डहरू | IEC 60204-1, EN 60204-1 |
| सञ्चालन अवस्था: परिवेशको तापक्रम | -25 to +70 ℃-13 to +158 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| मूल्याङ्कन गरिएको परिचालन भोल्टेज (Ue) / मूल्याङ्कन गरिएको परिचालन वर्तमान (Ie) | Ue30V125V250VIeACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |
प्राविधिक विशिष्टताहरू र प्रदर्शन डेटा
स्थापना र सञ्चालन मार्गनिर्देश