| प्यारामीटर | मूल्य |
|---|---|
| वस्तु | Specifications |
| पीएफएचडी | 1.66 × 10-10(Note:Probability of dangerous failure per hour) |
| MTTFDLanguage | 100 years or more(Note:Mean time to dangerous failure (in years)) |
| तौल | Net weight: 250 g approx. |
| विवरणहरू | Applicantion expansion unit for the SF4B series |
| उत्पादन | Exclusive Control Unit for Safety Light Curtain |
| सामाग्री | Enclosure: ABS |
| भाग नम्बर | SF-C14EX |
| उत्पादनको नाम | Exclusive Control Unit for Safety Light Curtain SF-C10 |
| पावर भोल्टेज | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| उत्पादन नम्बर | SF-C14EX |
| परिवेशको आर्द्रता | 30 to 85 % RH, Storage: 30 to 95 % RH |
| नियन्त्रण कोटी | ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards |
| झट्का प्रतिरोध | 30 G acceleration in X, Y and Z directions three times each |
| बत्तीको आउटपुट म्युट गर्दै | Applicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit) |
| परिवेशको तापक्रम | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158 ℉ |
| जडान टर्मिनल | Detachable spring-cage terminal |
| हालको खपत | 0.2 A or less (Excluding Safety light curtain and other external connecting device) |
| कम्पन प्रतिरोध | 10 to 55 Hz frequency, 0.35 mm0.014 indouble amplitude in X, Y and Z directions for two hours each |
| इन्सुलेशन प्रतिरोध | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| लागू हुने मापदण्डहरू: जापान | JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe) |
| सीई मार्किंग निर्देशन अनुपालन | Machinery Directive, EMC Directive, RoHS Directive |
| लागू हुने मापदण्डहरू: युरोप (EU) | EN 55011, EN ISO 13849-1 (Category 4, PLe) |
| जडान गर्न मिल्ने सुरक्षा प्रकाश पर्दाहरू | SF4B / SF4B-Gseries(Note:The handy-controllerSFB-HC(optional) cannot be used withSF-C14EX-01.) |
| लागू हुने मापदण्डहरू: उत्तर अमेरिका | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) |
| म्युटिङ ल्याम्प आउटपुट: सुरक्षा सर्किट | Incorporated |
| लागू हुने मापदण्डहरू: अन्तर्राष्ट्रिय मापदण्ड | IEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe) |
| वातावरणीय प्रतिरोध: सुरक्षाको डिग्री | Enclosure: IP40Terminal: IP20 |
| वातावरणीय प्रतिरोध: डाइलेक्ट्रिक शक्ति भोल्टेज | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| सुरक्षा आउटपुटहरू (सुरक्षा आउटपुट १, सुरक्षा आउटपुट २, सुरक्षा आउटपुट ३) | PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 200 mA・Applied voltage: same as supply voltage(between the safety output and +V)・Residual voltage: 2 V or less (at 200 mA source current)<When NPN output is selected>・Maximum sink current: 200 mA・Applied voltage: same as supply voltage(between the safety output and 0 V)・Residual voltage: 2 V or less (at 200 mA sink current) |
| सुरक्षा आउटपुटहरू (सुरक्षा आउटपुट १, सुरक्षा आउटपुट २, सुरक्षा आउटपुट ३): प्रतिक्रिया समय | OFF response: 14 ms or less (Safety output 1 and 2: including the response time of the Safety light curtain)ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note)(Note) The auto-reset cannot be used with safety output 3. |
| सहायक आउटपुटहरू (सहायक आउटपुट १, सहायक आउटपुट २, सहायक आउटपुट ३, सहायक आउटपुट ४) | PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and +V)・Residual voltage: 2 V or less (at 60 mA source current)<When NPN output is selected>・Maximum sink current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and 0 V)・Residual voltage: 2 V or less (at 60 mA sink current) |
| सुरक्षा आउटपुटहरू (सुरक्षा आउटपुट १, सुरक्षा आउटपुट २, सुरक्षा आउटपुट ३): सञ्चालन मोड (आउटपुट सञ्चालन) | Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is validOFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid |
| सुरक्षा आउटपुटहरू (सुरक्षा आउटपुट १, सुरक्षा आउटपुट २, सुरक्षा आउटपुट ३): सुरक्षा सर्किट (सर्ट-सर्किट सुरक्षा) | Incorporated |
| सहायक आउटपुटहरू (सहायक आउटपुट १, सहायक आउटपुट २, सहायक आउटपुट ३, सहायक आउटपुट ४): सञ्चालन मोड (आउटपुट सञ्चालन) | Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is validAuxiliary output 2: ON when the override function is invalid, OFF when the override function is validAuxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is errorAuxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition(Note:The auxiliary output incorporated in theSF4Bseries is output.) |
| सहायक आउटपुटहरू (सहायक आउटपुट १, सहायक आउटपुट २, सहायक आउटपुट ३, सहायक आउटपुट ४): सुरक्षा सर्किट (सर्ट-सर्किट सुरक्षा) | Incorporated |