SF2C-H24-N - SF2C-H24-N PANASONIC Ultra-slim Safety Light Curtain Typ2 (PLc SIL1), Hand Protection, protective height 480..
स्टकमा उपलब्ध लोकप्रिय उत्पादन

SF2C-H24-N

SF2C-H24-N PANASONIC Ultra-slim Safety Light Curtain Typ2 (PLc SIL1), Hand Protection, protective height 480..

$0.00USD
3209 स्टकमा
मुख्य विशिष्टताहरू
वस्तु:Specifications
पीएफएचडी:3.99 × 10-9(Note) Probability of dangerous failure per hour.
केबल:0.16 mm25-core heat-resistant PVC cable, 3 m 9.842 ft long
MTTFDLanguage:100 years or more(Note) Mean time to dangerous failure.
आपूर्तिकर्ता जानकारी
PANASONIC
PANASONIC
उत्पादहरू: 4316
सामान्यतया २-३ कार्यदिवसभित्र पठाइन्छ
गुणस्तर ग्यारेन्टी
छिटो शिपिङ
प्राविधिक सहयोग

प्राविधिक विशिष्टताहरू

प्यारामीटरमूल्य
वस्तुSpecifications
पीएफएचडी3.99 × 10-9(Note) Probability of dangerous failure per hour.
केबल0.16 mm25-core heat-resistant PVC cable, 3 m 9.842 ft long
MTTFDLanguage100 years or more(Note) Mean time to dangerous failure.
विवरणहरूHand protection type Min. sensing object ø25 mmø0.984 in(20 mm0.787 inbeam pitch)
उत्पादनUltra-slim Light Curtain [Type 2 PLc SIL1]
सामाग्रीEnclosure: Polycarbonate alloySensing surface: Polycarbonate alloyMS-SFC-1 (Standard mounting bracket): Stainless steel (SUS)
बिम पिच20 mm0.787 in
सामानहरूMS-SFC-1 (Standard mounting bracket): 1 setSF4C-TR25 (Test rod): 1 No.
भाग नम्बरSF2C-H24-N
उत्पादनको नामUltra-slim Light Curtain [Type2 PLc SIL1] SF2C
पावर भोल्टेज24 V DC plus or minus 20 % Ripple P-P 10 % or less
प्रतिक्रिया समयOFF response: 20 ms or lessON response: 80 to 100 ms
उत्पादन नम्बरSF2C-H24-N
केबल एक्सटेन्सनExtension up to total 50m is possible for 0.3mm2or more, cable
सञ्चालन दायरा0.1 to 3 m0.328 to 9.843 ft
परिवेशको आर्द्रता30 to 85 % RH, Storage: 30 to 85 % RH
उत्सर्जन तत्वInfrared LED (Peak emission wavelength: 850 nm0.034 mil)
प्रदूषणको डिग्री3
झट्का प्रतिरोध300 m / s2acceleration (30 G approx.) in X, Y and Z directions three times each
सुरक्षात्मक उचाइ480 mm18.898 in
सञ्चालन उचाइ2, 000 m6561.680 ftor less(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
परिवेश रोशनीIncandescent light: 5,000 ℓx or less at the light-receiving face
परिवेशको तापक्रम-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: - 25 to +60 ℃- 13 to +140 ℉
लकआउट आउटपुट (SSD)- Maximum sink current: 60mA- Applied voltage: same as supply voltage (between the lockout output and -0V)- Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable)- Leakage current: 200micro A or less (power supply OFF condition)- Maximum load capacity: 2.2micro F (No load to maximum output current)- Load wiring resistance: 3Ω or less
न्यूनतम सेन्सिङ वस्तुø25 mmø0.984 inopaque object
परीक्षण इनपुट प्रकार्यIncorporated
नियन्त्रण आउटपुट (OSSD)- Maximum sink current: 200mA- Applied voltage: same as supply voltage (between the control output and -0V)- Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable)- Leakage current: 200micro A or less (power supply OFF condition)- Maximum load capacity: 2.2micro F (No load to maximum output current)- Load wiring resistance: 3Ω or less
बीम च्यानलहरूको संख्या24
कम्पन प्रतिरोध10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each
इन्सुलेशन प्रतिरोध20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure
प्रभावकारी एपर्चर कोणplus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
लागू हुने मापदण्डहरू: जापानJIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1)
सीई मार्किंग निर्देशन अनुपालनMachinery Directive, EMC Directive, RoHS Directive
लागू हुने मापदण्डहरू: युरोप (EU)EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate.
हस्तक्षेप रोकथाम कार्यIncorporated
लागू हुने मापदण्डहरू: उत्तर अमेरिकाANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06(Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark.
लकआउट आउटपुट (SSD): सञ्चालन मोडON during normal operation, OFF during lockout(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF.
नियन्त्रण आउटपुट (OSSD): सञ्चालन मोडON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)
ठूलो बहुउद्देश्यीय सूचक प्रकार्यIncorporated
लकआउट आउटपुट (SSD): सुरक्षा सर्किटIncorporated
नियन्त्रण आउटपुट (OSSD): सुरक्षा सर्किटIncorporated
खुद तौल (इमिटर र रिसीभरको कुल)520 g approx.
लागू हुने मापदण्डहरू: अन्तर्राष्ट्रिय मापदण्डIEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1)
वातावरणीय प्रतिरोध: सुरक्षाको डिग्रीIP65, IP67 (IEC)
हालको खपत: ठूलो बहुउद्देश्यीय सूचक बल्छEmitter: 45 mA or lessReceiver: 40 mA or less
हालको खपत: ठूला बहुउद्देश्यीय सूचक बत्तीहरू निभ्छन्Emitter: 35 mA or lessReceiver: 35 mA or less

उत्पादन विवरण

More details
मुख्य विशेषताहरू
  • औद्योगिक स्तरको गुणस्तर
  • RoHS अनुरूप
  • सीई प्रमाणित
  • १-वर्षीय वारंटी

उत्पादन कागजातहरू

डेटासिट

प्राविधिक विशिष्टताहरू र प्रदर्शन डेटा

प्रयोगकर्ता म्यानुअल

स्थापना र सञ्चालन मार्गनिर्देश