सेवा समय: सोमबार देखि शुक्रबार ९:००-१८:००
HC-M-HS 200/70-MOD-BU-PE - HC-M-HS 200/70-MOD-BU-PE 1636910 PHOENIX CONTACT Contact insert module
स्टकमा उपलब्ध लोकप्रिय उत्पादन

HC-M-HS 200/70-MOD-BU-PE

HC-M-HS 200/70-MOD-BU-PE 1636910 PHOENIX CONTACT Contact insert module

$0.00USD
3754 स्टकमा
मुख्य विशिष्टताहरू
GTIN सम्बन्धी जानकारी:4046356095228
नोट:Made to Order (non-returnable)
अर्डरकी:1636910
क्याटलग पृष्ठ:Page 551 (C-4-2015)
आपूर्तिकर्ता जानकारी
उत्पादहरू: 0
सामान्यतया २-३ कार्यदिवसभित्र पठाइन्छ
गुणस्तर ग्यारेन्टी
छिटो शिपिङ
प्राविधिक सहयोग

प्राविधिक विशिष्टताहरू

प्यारामीटरमूल्य
GTIN सम्बन्धी जानकारी4046356095228
नोटMade to Order (non-returnable)
अर्डरकी1636910
क्याटलग पृष्ठPage 551 (C-4-2015)
प्याकिङ युनिट1 pc
उत्पत्तिको देशDE (Germany)
कस्टम ट्यारिफ नम्बर85366990
(परिवेशको अवस्था)16 mm (70 mm²)
सम्पर्क सामग्री (सामान्य)Copper alloy
मूल्याङ्कन गरिएको वर्तमान (आयामहरू)200 A
चौडाइ (मुख्य व्यावसायिक डेटा)34.2 mm
उचाइ (मुख्य व्यावसायिक डेटा)54.3 mm
लम्बाइ (मुख्य व्यावसायिक डेटा)29.4 mm
जडान प्रोफाइल (आयामहरू)PE
सम्पर्क वाहक सामग्री (सामान्य)PC
सम्पर्क सतह सामग्री (सामान्य)Ag
शृङ्खला (यान्त्रिक विशेषताहरू)HC-M-HS
प्रति टुक्रा तौल (प्याकिङ बाहेक)95.100 g
षट्कोणीय सकेट (परिवेश अवस्था)WAF 5
कडा टर्क (परिवेशको अवस्था)9 Nm (40 - 50 mm²)
जडान (यान्त्रिक विशेषताहरू)Note on axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Use of cables with a geometric cross section that differs greatly from the nominal cross section of the cable should be checked before use.The wiring space for axial screw technology is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) should be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The wires should be inserted as far as they will go into the contact chamber (until the insulation touches the contact). Hold the wires in position and use the socket wrench to tighten. The used wire end should be cut off before connecting again. The connection screw may only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable should be mechanically intercepted at an appropriate distance from the connection point (e.g., by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly. The module cannot be used simultaneously with HC-B..-TMB-SD-IP65 and HC-B..-TMS-SD-IP65 protective covers.PE mounting plateThe PE plate must be pressed hard against the swing frame using the 4 screws. First loosen the 4 screws of the PE plate and then tighten them again once the module is fixed in the swing frame.
न्यूनतम आवास उचाइ (परिवेशको अवस्था)72 mm
कन्डक्टर क्रस सेक्सन (परिवेशको अवस्था)40 mm² ... 70 mm² (The cross section specification refers to the geometric cross section of the cable used)
जडान विधि (यान्त्रिक विशेषताहरू)Axial screw connection
मानक (सामग्री डेटा) सँगको सम्बन्धमा जडानUL
सम्मिलन/निकासी चक्र (परिवेश अवस्था)≥ 500
जडान क्रस सेक्सन AWG (परिवेश अवस्था)1 ... 00
विधानसभा निर्देशनहरू (यान्त्रिक विशेषताहरू)- Use only flexible conductors,- Connection of wires with 5 mm an Allen wrench,- Housing height h ≥ 72 mm,- Connectors may only be operated without load/voltage.
मोड्युल स्लटहरूको संख्या (यान्त्रिक विशेषताहरू)2
UL ९४ (सामग्री डेटा) अनुसार ज्वलनशीलता मूल्याङ्कनV0
इन्सुलेशन सहित तार व्यास (परिवेश अवस्था)12 mm (40 mm²)
परिवेशको तापक्रम (सञ्चालन) (विद्युत विशेषताहरू)-40 °C ... 125 °C
व्यक्तिगत तारको स्ट्रिपिङ लम्बाइ (परिवेशको अवस्था)16 mm
UL ९४ अनुसार ज्वलनशीलता मूल्याङ्कन (यांत्रिक विशेषताहरू)V0

उत्पादन विवरण

More details
मुख्य विशेषताहरू
  • औद्योगिक स्तरको गुणस्तर
  • RoHS अनुरूप
  • सीई प्रमाणित
  • १-वर्षीय वारंटी

उत्पादन कागजातहरू

डेटासिट

प्राविधिक विशिष्टताहरू र प्रदर्शन डेटा

प्रयोगकर्ता म्यानुअल

स्थापना र सञ्चालन मार्गनिर्देश

Top