| प्यारामीटर | मूल्य |
|---|---|
| EAN लन्च | 4011209638501 |
| युपीसी | 040892553642 |
| ईटीआईएम | 5 |
| विचार | 4 |
| गहिराई | 155 mm |
| चौडाइ | 120 mm |
| युएनएसपीएससी | 14 |
| ईक्लास | 6 |
| उचाइ | 119 mm |
| ● note | for contactor disconnection |
| — ठोस | 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²) |
| समूह कोड | R711 |
| यात्रा कक्षा | CLASS 5E, 10E, 20E and 30E adjustable |
| ● २४ V मा | 4 A |
| ● ६० V मा | 0.55 A |
| ● अधिकतम | IMotor < upper current setting value x 3.5 |
| ● न्यूनतम | IMotor > lower current setting value |
| धातु कारक | L-O----- |
| ● ११० V मा | 4 A |
| ● at 120 V | 4 A |
| ● at 125 V | 4 A |
| ● २२० V मा | 0.11 A |
| ● २३० V मा | 3 A |
| मिति ५/१४/२०२२ | Subject to change without notice© Copyright Siemens 2022 |
| उत्पादन समूह | 5808 |
| उत्पादन वर्ग | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| परिमाण एकाइ | 1 Piece |
| कमोडिटी कोड | 85364900 |
| उत्पादन परिवार | 3RB20, 3RB21 for standard applications |
| अन्तिम पटक परिमार्जन गरिएको: | 2/9/2022 |
| खुद तौल (किलोग्राम) | 1,613 Kg |
| सञ्चालन शक्ति | |
| thermal current | 250 A |
| ● मूल्याङ्कन गरिएको मान | 1 000 V |
| बन्धन विधि | Contactor mounting/stand-alone installation |
| shock resistance | 15g / 11 ms |
| उत्पत्तिको देश | Germany |
| समुद्री / ढुवानी | other |
| माउन्टिङ स्थिति | any |
| सञ्चालन भोल्टेज | |
| tightening torque | |
| LKZ_FDB/ क्याटलग आईडी | CC-IC10 |
| प्याकेजिङ मात्रा | 1 |
| उत्पादनको ब्रान्ड नाम | SIRIUS |
| ● भण्डारणको समयमा | -40 ... +80 °C |
| प्याकेजिङ आयाम | 151,00 x 158,00 x 175,00 |
| उत्पादन विवरण | Overload relay 55...250 A for motor protection Size S10/S12, CLASS 5...30E Contactor mounting/stand-alone installation Main circuit: busbar connection Auxiliary circuit: Screw terminal Manual-Automatic-Reset Internal ground fault detection |
| परिवेशको तापक्रम | |
| उत्पादन पदनाम | solid-state overload relay |
| vibration resistance | 1-6 Hz, 15 mm; 6-500 Hz, 20 m/s²; 10 cycles |
| ● सञ्चालनको समयमा | -25 ... +60 °C |
| ● ढुवानीको समयमा | -40 ... +80 °C |
| - ठोस वा अड्किएको | 1x (0,5 ... 4 mm²), 2x (0,5 ... 2,5 mm²) |
| ● मुख्य सम्पर्कहरूको लागि | M10 |
| conducted interference | |
| size of overload relay | S10, S12 |
| उत्पादन जीवनचक्र (PLM) | PM300:Active Product |
| फ्यूज लिङ्कको डिजाइन | |
| सामान्य उत्पादन स्वीकृति | EMC |
| रिलिज वर्ग (EF006668) | Adjustable |
| उत्पादन प्रकारको पदनाम | 3RB2 |
| तापक्रम क्षतिपूर्ति | -25 ... +60 °C |
| ● ४८० V मूल्याङ्कन गरिएको मानमा | 250 A |
| ● ६०० V मूल्याङ्कन गरिएको मानमा | 250 A |
| निर्यात नियन्त्रण नियमहरू | AL : N / ECCN : N |
| माउन्टिङ विधि (EF000003) | - |
| ● सहायक सम्पर्कहरूको लागि | |
| मानक लिड टाइम एक्स-वर्क्स | 60 Day/Days |
| कच्चा पदार्थको लागि अधिभार | None |
| प्याकेज आकार मापनको एकाइ | MM |
| ● मुख्य करेन्ट सर्किटको लागि | busbar connection |
| पदार्थ निषेध (मिति) | 07/01/2006 |
| विद्युतीय जडानको प्रकार | |
| For use in hazardous locations | Declaration of Conformity |
| design of the auxiliary switch | integrated |
| ओभरलोड रिलीजको डिजाइन | electronic |
| प्रकार्य इनपुट रिसेट गर्नुहोस् (EF011940) | - |
| सञ्चालन आवृत्ति मूल्याङ्कन गरिएको मान | 50 ... 60 Hz |
| सञ्चालन वर्तमान मूल्याङ्कन गरिएको मान | 250 A |
| ● according to IEC 60068-2-27 | 15g / 11 ms; Signaling contact 97 / 98 in position "Tripped": 8g / 11 ms |
| ● AC-3e मूल्याङ्कन गरिएको अधिकतम मानमा | 1 000 V |
| सञ्चालनको समयमा सापेक्षिक आर्द्रता | 10 ... 95 % |
| समायोज्य वर्तमान दायरा (EF008211) | ['55', '250'] |
| स्वचालित प्रकार्य रिसेट गर्नुहोस् (EF011941) | - |
| ● for AC motors at 500 V at 50 Hz | 45 ... 160 kW |
| ● for AC motors at 690 V at 50 Hz | 55 ... 250 kW |
| ● for remote-reset function at DC | 24 V |
| display version for switching status | Slide switch |
| वृद्धि भोल्टेज प्रतिरोध मूल्याङ्कन गरिएको मान | 8 kV |
| लेख नम्बर (बजार अनुहार नम्बर) | 3RB2163-4GC2 |
| प्रकार्य रिसेट गर्नुहोस् पुश-बटन (EF011942) | - |
| एक्चुएटिंगको लागि भोल्टेज प्रकार (EF008242) | - |
| ● सहायक र नियन्त्रण सर्किटको लागि | screw-type terminals |
| WEEE (२०१२/१९/EU) फिर्ता लिने दायित्व | Yes |
| — असाइनमेन्ट २ को प्रकार आवश्यक छ | gG: 500 A |
| ● between main and auxiliary circuit | 600 V |
| IEC 81346-2 अनुसार सन्दर्भ कोड | F |
| मुख्य विद्युत सर्किटको लागि पोलहरूको संख्या | 3 |
| — समन्वय १ प्रकार आवश्यक भएको | gG: 500 A, Class L: 700 A |
| ● सहायक सम्पर्कहरूको लागि AWG केबलहरूमा | 2x (20 ... 14) |
| ● for 3-phase motors at 400 V at 50 Hz | 30 ... 132 kW |
| ● of the auxiliary and control contacts | M3 |
| ● between auxiliary and auxiliary circuit | 300 V |
| ● due to burst according to IEC 61000-4-4 | 2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3 |
| design of the thread of the connection screw | |
| ३-फेज एसी मोटरको लागि फुल-लोड करेन्ट (FLA) | |
| number of CO contacts for auxiliary contacts | 0 |
| सहायक सम्पर्कहरूको लागि NC सम्पर्कहरूको संख्या | 1 |
| सहायक सम्पर्कहरूको लागि NO सम्पर्कहरूको संख्या | 1 |
| जडानयोग्य कन्डक्टर क्रस-सेक्शनहरूको प्रकार | |
| — कोर एन्ड प्रशोधनको साथ राम्रोसँग स्ट्र्यान्ड गरिएको | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
| ● for main contacts with screw-type terminals | 20 ... 22 N·m |
| मूल्याङ्कन गरिएको नियन्त्रण आपूर्ति भोल्टेज Us at DC (EF003980) | ['-', '-'] |
| operational current at AC-3e at 400 V rated value | 250 A |
| electrostatic discharge according to IEC 61000-4-2 | 6 kV contact discharge / 8 kV air discharge |
| operational current of auxiliary contacts at AC-15 | |
| operational current of auxiliary contacts at DC-13 | |
| size of contactor can be combined company-specific | S10, S12 |
| field-based interference according to IEC 61000-4-3 | 10 V/m |
| type of voltage supply via input/output link master | No |
| क्षेत्र विशिष्ट मूल्य समूह / मुख्यालय मूल्य समूह | 41G / 41G |
| UL अनुसार सहायक सम्पर्कहरूको सम्पर्क मूल्याङ्कन | B600 / R300 |
| IEC ६०५२९ अनुसार अगाडिको भागमा स्पर्श सुरक्षा | finger-safe, for vertical contact from the front with box terminal/cover |
| ● for auxiliary contacts with screw-type terminals | 0.8 ... 1.2 N·m |
| ● मुख्य सर्किटको सर्ट-सर्किट सुरक्षाको लागि | |
| रेटेड नियन्त्रण आपूर्ति भोल्टेज Us at AC 50HZ (EF003978) | ['-', '-'] |
| रेटेड नियन्त्रण आपूर्ति भोल्टेज Us at AC 60HZ (EF003979) | ['-', '-'] |
| समुद्र सतहभन्दा अधिकतम उचाइमा स्थापना उचाइ | 2 000 m |
| IEC ६०५२९ अनुसार अगाडिको सुरक्षा वर्ग IP | IP00; IP20 with box terminal/cover |
| मुख्य सर्किटको विद्युतीय जडानको प्रकार (EF006819) | Other |
| ATEX निर्देशन २०१४/३४/EU अनुसार सुरक्षाको प्रकार | Ex II (2) G [Ex e] [Ex d] [Ex px] ; Ex II (2) D [Ex t] [Ex p] |
| response time of the grounding protection in settled state | 1 000 ms |
| response value current of the grounding protection minimum | 0.75 x IMotor |
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV (line to earth) corresponds to degree of severity 3 |
| arrangement of electrical connectors for main current circuit | Top and bottom |
| परिवर्तन-सम्पर्कको रूपमा सहायक सम्पर्कहरूको संख्या (EF003531) | 0 |
| ● due to high-frequency radiation according to IEC 61000-4-6 | 10 V in frequency range 0.15 to 80 MHz, modulation 80 % AM with 1 kHz |
| AC रेटेड मानमा प्रदूषण डिग्री ३ सहितको इन्सुलेशन भोल्टेज | 1 000 V |
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV (line to line) corresponds to degree of severity 3 |
| सामान्यतया खुला सम्पर्कको रूपमा सहायक सम्पर्कहरूको संख्या (EF001376) | 1 |
| ATEX निर्देशन २०१४/३४/EU अनुसार उपयुक्तताको प्रमाणपत्र | PTB 06 ATEX 3001 |
| ● सहायक स्विचको सर्ट-सर्किट सुरक्षाको लागि आवश्यक | fuse gG: 6 A |
| सामान्य रूपमा बन्द सम्पर्कको रूपमा सहायक सम्पर्कहरूको संख्या (EF001377) | 1 |
| RoHS निर्देशन अनुसार पदार्थ प्रतिबन्धहरूको अनुपालन | Since: 01.07.2006 |
| product component removable terminal for auxiliary and control circuit | Yes |
| पहुँच धारा ३३ उम्मेदवारहरूको हालको सूची अनुसार जानकारी गराउने कर्तव्य | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| operating range of the grounding protection relating to current set value | |
| वर्तमान-निर्भर ओभरलोड रिलीजको समायोज्य वर्तमान प्रतिक्रिया मान वर्तमान | 55 ... 250 A |
| maximum permissible voltage for safe isolation in networks with grounded star point | |
| General Product ApprovalEMCConfirmationFor use in hazardous locationsDeclaration of ConformityTest CertificatesMarine / ShippingType Test Certificates/Test ReportSpecial Test CertificateMarine / ShippingotherMiscellaneousConfirmation | General Product Approval |
प्राविधिक विशिष्टताहरू र प्रदर्शन डेटा
स्थापना र सञ्चालन मार्गनिर्देश